1. Set time of day:
PROGRAMMING PROCEDURES:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
STEP 1 – Press
CLOCK.
STEP 2CURRENT TIME (HOUR): Set the hour of the day using + or buttons. AM/PM toggles after 12.
Press
NEXT to go to step 3.
STEP 3CURRENT TIME (MINUTES): Set the minutes using + or buttons. If it is desired to back up to the
previous step press
REGEN button once. Pressing NEXT will exit CLOCK and return to the general operating
display (page 9).
1 2 3
2. Programming:
NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered.
STEP 1 – Press
NEXT and + simultaneously for 3 seconds.
STEP 2HARDNESS: Set the amount of hardness in grains per gallon (default 20)
using the + or buttons. The allowable range is from 1 to 150 in 1 grain
increments.
NOTE: If a resin media is used in the softener, increase the grains per
gallon if soluble iron is present (1 ppm = 4 gpg). This display will show
“–nA– (not available)” if “FILTER” is selected or if “AUTO” is not factory set.
Press
NEXT to go to step 3.
Press
REGEN if you want to exit.
STEP 3DAY OVERRIDE: The manufacturer has factory set 12 DAYS as the
default. This is the maximum number of days between regenerations.
If this is set to “OFF”, regeneration initiation is based solely on gallons
used. If any number is set (allowable range from 1 to 28), a regeneration
initiation will be called for on that day even if a sufficient number of
gallons were not used to call for a regeneration.
Set Day Override using + or buttons (12 is recommended):
• set number of days between regeneration (1 to 28); or
set to “OFF”.
Press
NEXT to go to step 4.
Press REGEN if you need to return to the previous step.
STEP 4REGENERATION HOUR: The manufacturer has factory set 2:00 A.M.
as the default. This is the hour of day for regeneration and can be reset by
using + or buttons. “AM/PM” toggles after 12. The default time is 2:00
a.m. (recommended for a normal household).
Press
NEXT to go to step 5.
Press REGEN if you need to return to the previous step.
1
2
3
4